Price search results for Eaton 106876 LS S11 ZB Safety button 400 V 6 A IP66 1 pcs
Additional technical information: Power loss of the apparatus, current-dependant [PVID]: 0 W.Power loss per pole, current-dependant...read more
Subscribe
Additional technical information: Power loss of the apparatus, current-dependant [PVID]: 0 W.
Power loss per pole, current-dependant [PVID]: 0.
17 W.
Static power loss, current independant [PVS]: 0 W.
Loss rating [PvE]: 0 W.
Type identifier: LS(4)…ZBRated operating current [IE]: 0.
3 A.
Overvoltage category/pollution degree III/3Connection cross-sections: 1 x (0.
5 - 1.
5)2 x (0.
5 - 1.
5) mm2Output electronic: no.
Equipment: Complete unitRated operating current IE at AC-15, 125 V: 6 A.
Rated operating current IE at AC-15, 230 V: 6 A.
Rated operating current IE at AC-15, 24 V: 10 A.
Rated operating current IE at DC-13, 125 V: 0.
8 A.
Rated operating current IE at DC-13, 230 V: 0.
3 A.
Rated operating current IE at DC-13, 24 V: 3 A.
Rated surge voltage resistance [Uimp]: 4000 V ACOperating frequency [switching cycles/h]: ≦ 1800Housing design: SquareClimatic resistance: Humidity heat, constant according to IEC 60068-2-78, humidity heat, cyclic according to IEC 60068-2-30Short-circuit resistance according to IEC/EN 60947-5-1: 6 A GG/GLMains frequency: Max.
400 HzSwitching function: Slow-acting switchShock resistance (half-sine pulse 20 ms): 25 gRepeat accuracy ± 0.
15 mmForced opening: Yes1 kA conditional short circuit current; Connection (components): Spring-loaded heavy duty connector; Contact type (LOV): 1 maker, 1 breaker; Dimensions (additional text): Casing; Durability: 1.
5 x 10 6 cycles; IP rating: IP66; Material: Plastic; Max.
temperature: +70 °C; Min.
temperature: -25 °C; Product size (height): 96 mm; Product size (length): 33.
35 mm; Product size (width): 30 mm; Switching current (max.
): 6 A; Switching voltage: 400 V
Power loss per pole, current-dependant [PVID]: 0.
17 W.
Static power loss, current independant [PVS]: 0 W.
Loss rating [PvE]: 0 W.
Type identifier: LS(4)…ZBRated operating current [IE]: 0.
3 A.
Overvoltage category/pollution degree III/3Connection cross-sections: 1 x (0.
5 - 1.
5)2 x (0.
5 - 1.
5) mm2Output electronic: no.
Equipment: Complete unitRated operating current IE at AC-15, 125 V: 6 A.
Rated operating current IE at AC-15, 230 V: 6 A.
Rated operating current IE at AC-15, 24 V: 10 A.
Rated operating current IE at DC-13, 125 V: 0.
8 A.
Rated operating current IE at DC-13, 230 V: 0.
3 A.
Rated operating current IE at DC-13, 24 V: 3 A.
Rated surge voltage resistance [Uimp]: 4000 V ACOperating frequency [switching cycles/h]: ≦ 1800Housing design: SquareClimatic resistance: Humidity heat, constant according to IEC 60068-2-78, humidity heat, cyclic according to IEC 60068-2-30Short-circuit resistance according to IEC/EN 60947-5-1: 6 A GG/GLMains frequency: Max.
400 HzSwitching function: Slow-acting switchShock resistance (half-sine pulse 20 ms): 25 gRepeat accuracy ± 0.
15 mmForced opening: Yes1 kA conditional short circuit current; Connection (components): Spring-loaded heavy duty connector; Contact type (LOV): 1 maker, 1 breaker; Dimensions (additional text): Casing; Durability: 1.
5 x 10 6 cycles; IP rating: IP66; Material: Plastic; Max.
temperature: +70 °C; Min.
temperature: -25 °C; Product size (height): 96 mm; Product size (length): 33.
35 mm; Product size (width): 30 mm; Switching current (max.
): 6 A; Switching voltage: 400 V